import functools import logging import os import signal import subprocess import sys import threading import time from datetime import datetime import pytest from PIL import ImageChops import ramscreen.__main__ as main_module from ramscreen.__main__ import main, run from ramscreen.config import Config from ramscreen.meminfo import App, Memory from ramscreen.render import render, render_stopped GIB = 2**30 MEM = Memory(total=16 * GIB, available=8 * GIB, swap_total=2 * GIB, swap_free=GIB) APPS = [App("firefox", GIB)] NOW = datetime(2026, 10, 14, 12, 0) FAST = Config(memory_interval=0, apps_interval=10) class FakeLcd: def __init__(self, open_failures=0, show_failures=()): self.calls = [] self.shown = [] # (x, y, Bild) self.open_failures = open_failures self.show_failures = set(show_failures) self._show_count = 0 def open(self): self.calls.append("open") if self.open_failures > 0: self.open_failures -= 1 raise OSError("kein Gerät") def close(self): self.calls.append("close") def set_orientation_portrait(self): self.calls.append("orientation") def set_brightness(self, percent): self.calls.append(("brightness", percent)) def show(self, image, x, y): index = self._show_count self._show_count += 1 if index in self.show_failures: raise OSError("Schreibfehler") self.calls.append("show") self.shown.append((x, y, image)) def stop_after(stop, iterations): count = 0 def read_memory(): nonlocal count count += 1 if count >= iterations: stop.set() return MEM return read_memory def run_fake(lcd, iterations, cfg=FAST, **kwargs): stop = threading.Event() kwargs.setdefault("top_apps", lambda n: APPS) run(cfg, lcd, stop, read_memory=stop_after(stop, iterations), now=lambda: NOW, reconnect_delay=0, **kwargs) def sizes(lcd): return [(x, y, img.size) for x, y, img in lcd.shown] def test_normaler_ablauf(): lcd = FakeLcd() run_fake(lcd, iterations=2) assert lcd.calls[:3] == ["open", "orientation", ("brightness", 20)] # 1. Durchlauf Vollbild, 2. Durchlauf unverändert → nichts, dann Endbildschirm als Vollbild assert sizes(lcd) == [(0, 0, (320, 480)), (0, 0, (320, 480))] assert lcd.calls[-1] == "close" assert lcd.calls.count("open") == 1 def test_schreibfehler_fuehrt_zu_neuverbindung_und_vollbild(): lcd = FakeLcd(show_failures={0}) run_fake(lcd, iterations=2) assert lcd.calls.count("open") == 2 assert lcd.calls[:6] == ["open", "orientation", ("brightness", 20), "close", "open", "orientation"] assert sizes(lcd)[0] == (0, 0, (320, 480)) def test_display_beim_start_nicht_da(): lcd = FakeLcd(open_failures=2) run_fake(lcd, iterations=1) assert lcd.calls.count("open") == 3 assert sizes(lcd)[0] == (0, 0, (320, 480)) def test_stoppen_waehrend_wartezeit_beendet_sofort(): lcd = FakeLcd(open_failures=10**6) stop = threading.Event() t = threading.Thread( target=run, args=(FAST, lcd, stop), kwargs={"read_memory": lambda: MEM, "top_apps": lambda n: APPS, "now": lambda: NOW, "reconnect_delay": 5}, ) t.start() time.sleep(0.2) stop.set() t.join(timeout=2) assert not t.is_alive() assert "show" not in lcd.calls # nie verbunden → kein Endbildschirm def test_programmliste_nur_im_eigenen_intervall(): calls = [] def top_apps(n): calls.append(n) return APPS times = iter([0, 4, 8, 12, 16, 20]) run_fake(FakeLcd(), iterations=6, top_apps=top_apps, monotonic=lambda: next(times)) assert calls == [5, 5] # bei t=0 und t=12 def test_drehung_um_180_grad(): cfg = Config(memory_interval=0, rotate_180=True) lcd = FakeLcd() run_fake(lcd, iterations=1, cfg=cfg) expected = render(MEM, APPS, NOW, cfg).rotate(180) assert ImageChops.difference(lcd.shown[0][2], expected).getbbox() is None def test_unerwarteter_fehler_zeigt_endbildschirm_statt_altem_stand(): calls = 0 def top_apps(n): nonlocal calls calls += 1 if calls == 2: raise RuntimeError("unerwartet") return APPS times = iter([0, 20]) lcd = FakeLcd() with pytest.raises(RuntimeError): run_fake(lcd, iterations=10, top_apps=top_apps, monotonic=lambda: next(times)) # erstes Bild live, danach Endbildschirm als Vollbild, dann geschlossen assert sizes(lcd) == [(0, 0, (320, 480)), (0, 0, (320, 480))] assert ImageChops.difference(lcd.shown[-1][2], render_stopped(NOW)).getbbox() is None assert lcd.calls[-1] == "close" def test_endbildschirm_fehler_wird_abgefangen(): lcd = FakeLcd(show_failures={1}) # 0 = erstes Bild, 1 = Endbildschirm run_fake(lcd, iterations=1) assert lcd.calls[-1] == "close" def test_auffrischung_genau_nach_ablauf_des_intervalls(): # fällig 600 s nach dem Verbindungsaufbau, danach 600 s nach der letzten (hier verspäteten) Auffrischung times = iter([0, 599, 600, 1250, 1849, 1850]) lcd = FakeLcd() run_fake(lcd, iterations=6, monotonic=lambda: next(times)) assert lcd.calls == [ "open", "orientation", ("brightness", 20), "show", # t=0 "orientation", ("brightness", 20), "show", # t=600 "orientation", ("brightness", 20), "show", # t=1250 "orientation", ("brightness", 20), "show", # t=1850 "show", "close", # Endbildschirm ] assert sizes(lcd) == [(0, 0, (320, 480))] * 5 # unverändertes Bild trotzdem als Vollbild def test_nach_neuverbindung_beginnt_auffrischungsintervall_neu(): # Bild 0 scheitert bei t=0, Wiederverbinden bei t=30 → nächste Auffrischung erst bei t=90, nicht bei t=60 times = iter([0, 0, 30, 30, 89, 90]) # Durchlauf, Fehler, Ausfalldauer, dann je Durchlauf lcd = FakeLcd(show_failures={0}) run_fake(lcd, iterations=4, monotonic=lambda: next(times), full_refresh_interval=60) assert lcd.calls == [ "open", "orientation", ("brightness", 20), "close", "open", "orientation", ("brightness", 20), "show", # t=30 "orientation", ("brightness", 20), "show", # t=90 "show", "close", ] class CommandFailingLcd(FakeLcd): """Der n-te Aufruf (ab 0) von Ausrichtung oder Helligkeit scheitert mit einem Schreibfehler.""" def __init__(self, command, index): super().__init__() self.failing = (command, index) self.counts = {"orientation": 0, "brightness": 0} def _send(self, command): index = self.counts[command] self.counts[command] += 1 if (command, index) == self.failing: raise OSError("Schreibfehler") def set_orientation_portrait(self): self._send("orientation") super().set_orientation_portrait() def set_brightness(self, percent): self._send("brightness") super().set_brightness(percent) @pytest.mark.parametrize( ("make_lcd", "sent"), [ (lambda: CommandFailingLcd("orientation", 1), []), # Aufruf 0 gehört zum Verbindungsaufbau (lambda: CommandFailingLcd("brightness", 1), ["orientation"]), (lambda: FakeLcd(show_failures={1}), ["orientation", ("brightness", 20)]), # Vollbild scheitert ], ids=["ausrichtung", "helligkeit", "vollbild"], ) def test_fehler_bei_auffrischung_fuehrt_zu_neuverbindung(make_lcd, sent): times = iter([0, 600, 600, 610, 610]) # Durchlauf, Auffrischung, Fehler, Ausfalldauer, Durchlauf lcd = make_lcd() run_fake(lcd, iterations=3, monotonic=lambda: next(times)) assert lcd.calls == [ "open", "orientation", ("brightness", 20), "show", *sent, "close", "open", "orientation", ("brightness", 20), "show", # Neuverbindung mit Vollbild "show", "close", ] class Clock: """Gesteuertes monotonic: liefert die zuletzt gesetzte Zeit.""" def __init__(self): self.t = 0.0 def __call__(self): return self.t class ScriptedLcd(FakeLcd): """open() stellt die Uhr auf den nächsten Zeitpunkt des Drehbuchs und scheitert mit dessen Meldung (None = Erfolg).""" def __init__(self, clock, script, show_failures=()): super().__init__(show_failures=show_failures) self.clock = clock self.script = list(script) def open(self): self.calls.append("open") self.clock.t, error = self.script.pop(0) if error is not None: raise OSError(error) @pytest.mark.parametrize( ("seconds", "text"), [(0, "0 s"), (42.4, "42 s"), (599.6, "10 min"), (610, "10 min 10 s"), (7200, "2 h"), (7535, "2 h 5 min")], ) def test_dauer_lesbar(seconds, text): assert main_module._duration(seconds) == text def log_lines(caplog): return [(r.levelname, r.getMessage()) for r in caplog.records if r.name == "ramscreen"] def test_ausfall_meldet_geaenderten_fehler_und_erinnert_alle_10_minuten(caplog): clock = Clock() lcd = ScriptedLcd(clock, [ (0, "kein Gerät"), (5, "kein Gerät"), # gleicher Fehler → still (10, "Zugriff verweigert"), # geänderter Fehler → sofort (609, "Zugriff verweigert"), # noch keine 10 min seit der letzten Meldung (610, "Zugriff verweigert"), # Erinnerung (1209, "Zugriff verweigert"), (1210, "Zugriff verweigert"), # nächste Erinnerung (1300, None), ]) with caplog.at_level(logging.INFO, logger="ramscreen"): run_fake(lcd, iterations=1, monotonic=clock) assert log_lines(caplog) == [ ("WARNING", "Display nicht erreichbar (kein Gerät), neuer Versuch in 0 s"), ("WARNING", "Display nicht erreichbar (Zugriff verweigert), neuer Versuch in 0 s"), ("WARNING", "Display weiterhin nicht erreichbar seit 10 min 10 s (letzter Fehler: Zugriff verweigert)"), ("WARNING", "Display weiterhin nicht erreichbar seit 20 min 10 s (letzter Fehler: Zugriff verweigert)"), ("INFO", "Display verbunden (/dev/turing-screen) nach 21 min 40 s Ausfall"), ("INFO", "Beendet"), ] assert lcd.script == [] def test_wiederverbinden_meldet_ausfalldauer_und_neuer_ausfall_wird_wieder_gemeldet(caplog): clock = Clock() # Bild 0 und das Vollbild nach dem ersten Wiederverbinden scheitern lcd = ScriptedLcd(clock, [(0, None), (5, None), (8, None)], show_failures={0, 1}) with caplog.at_level(logging.INFO, logger="ramscreen"): run_fake(lcd, iterations=3, monotonic=clock) assert log_lines(caplog) == [ ("INFO", "Display verbunden (/dev/turing-screen)"), ("WARNING", "Display nicht erreichbar (Schreibfehler), neuer Versuch in 0 s"), ("INFO", "Display verbunden (/dev/turing-screen) nach 5 s Ausfall"), ("WARNING", "Display nicht erreichbar (Schreibfehler), neuer Versuch in 0 s"), ("INFO", "Display verbunden (/dev/turing-screen) nach 3 s Ausfall"), ("INFO", "Beendet"), ] @pytest.fixture def display_calls(monkeypatch): """Ersetzt Display und Hauptschleife; ein Eintrag bedeutet, dass main() sie benutzt hätte.""" calls = [] monkeypatch.setattr(main_module, "Lcd", lambda port: calls.append(("Lcd", port))) monkeypatch.setattr(main_module, "run", lambda *args, **kwargs: calls.append("run")) return calls @pytest.mark.parametrize( ("text", "fragment"), [ ('top_n = 2.5\nrotate_180 = "false"\n', "top_n"), # ungültige Werte ("brightness = = 20\n", "line 1"), # TOML-Syntaxfehler ("[port\n", "line 1"), ], ) def test_ungueltige_konfiguration_beendet_mit_2_ohne_traceback( tmp_path, caplog, capsys, display_calls, text, fragment ): path = tmp_path / "config.toml" path.write_text(text, encoding="utf-8") with caplog.at_level(logging.INFO): assert main(["--config", str(path)]) == 2 errors = [r for r in caplog.records if r.levelno == logging.ERROR] assert len(errors) == 1 assert str(path) in errors[0].getMessage() assert fragment in errors[0].getMessage() assert errors[0].exc_info is None assert "Traceback" not in caplog.text + capsys.readouterr().err assert display_calls == [] def test_unlesbare_konfiguration_beendet_mit_2_ohne_traceback(tmp_path, caplog, capsys, display_calls): path = tmp_path / "verzeichnis.toml" path.mkdir() # existiert, lässt sich aber nicht als Datei lesen assert main(["--config", str(path)]) == 2 errors = [r for r in caplog.records if r.levelno == logging.ERROR] assert len(errors) == 1 assert str(path) in errors[0].getMessage() assert errors[0].exc_info is None assert "Traceback" not in caplog.text + capsys.readouterr().err assert display_calls == [] STOP_SIGNALS = (signal.SIGTERM, signal.SIGINT) @pytest.fixture def restore_signal_handlers(): saved = {sig: signal.getsignal(sig) for sig in STOP_SIGNALS} yield for sig, handler in saved.items(): signal.signal(sig, handler) @pytest.mark.parametrize("sig", STOP_SIGNALS) def test_signal_handler_blockiert_nicht_am_lock_des_events(restore_signal_handlers, sig): original = signal.getsignal(sig) stop = threading.Event() main_module._install_signal_handlers(stop) handler = signal.getsignal(sig) assert callable(handler) and handler is not original # Der echte Handler läuft im Hauptthread zwischen zwei Bytecodes, womöglich während stop.wait() # das nicht reentrante Lock des Events hält. Nachstellen lässt sich das nur über das private _cond. # Eigener Daemon-Thread: Blockiert der Handler wieder, scheitert nur dieser Test statt die Suite aufzuhängen. def handler_unter_lock(): with stop._cond: handler(sig, None) t = threading.Thread(target=handler_unter_lock, daemon=True) t.start() t.join(timeout=2) assert not t.is_alive(), "Signal-Handler blockiert am Lock des Events" assert stop.wait(timeout=2) @pytest.mark.parametrize("sig", STOP_SIGNALS) def test_signal_stoppt_hauptschleife_von_main(tmp_path, monkeypatch, restore_signal_handlers, sig): stops = [] monkeypatch.setattr(main_module, "Lcd", lambda port: None) monkeypatch.setattr(main_module, "run", lambda cfg, lcd, stop: stops.append(stop)) assert main(["--config", str(tmp_path / "fehlt.toml")]) == 0 # fehlende Datei → Standardwerte signal.getsignal(sig)(sig, None) assert stops[0].wait(timeout=2) def test_unerwarteter_fehler_beendet_main_mit_1_und_loggt_traceback( tmp_path, monkeypatch, caplog, restore_signal_handlers ): def read_memory(): raise RuntimeError("kaputt") path = tmp_path / "config.toml" path.write_text('port = "/dev/nicht-vorhanden"\n', encoding="utf-8") lcd = FakeLcd() monkeypatch.setattr(main_module, "Lcd", lambda port: lcd) monkeypatch.setattr(main_module, "run", functools.partial( run, read_memory=read_memory, top_apps=lambda n: APPS, now=lambda: NOW)) assert main(["--config", str(path)]) == 1 errors = [r for r in caplog.records if r.levelno >= logging.ERROR] assert len(errors) == 1 assert errors[0].exc_info[0] is RuntimeError assert "Traceback" in caplog.text assert "RuntimeError: kaputt" in caplog.text # das finally in run() greift weiterhin: Endbildschirm statt eingefrorenem Stand assert ImageChops.difference(lcd.shown[-1][2], render_stopped(NOW)).getbbox() is None assert lcd.calls[-1] == "close" @pytest.mark.parametrize(("journal", "prefix"), [("passend", "<3>"), ("unpassend", "")]) def test_main_logt_mit_prioritaet_nur_wenn_stderr_am_journal_haengt(tmp_path, journal, prefix): # Eigener Prozess, damit sys.stderr und os.environ wirklich die des Programms sind. # Ungültige Konfiguration: main() endet, bevor ein Display geöffnet würde. path = tmp_path / "config.toml" path.write_text('port = "/dev/nicht-vorhanden"\ntop_n = 0\n', encoding="utf-8") env = {key: value for key, value in os.environ.items() if key != "JOURNAL_STREAM"} with open(tmp_path / "stderr", "w+b") as err: st = os.fstat(err.fileno()) ino = st.st_ino if journal == "passend" else st.st_ino + 1 env["JOURNAL_STREAM"] = f"{st.st_dev}:{ino}" result = subprocess.run( [sys.executable, "-m", "ramscreen", "--config", str(path)], stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=err, env=env, cwd=tmp_path, timeout=30, ) err.seek(0) lines = err.read().decode().splitlines() assert result.returncode == 2 assert len(lines) == 1 assert lines[0].startswith(f"{prefix}ERROR Konfiguration {path} ist ungültig: top_n")